纺织学报 ›› 2018, Vol. 39 ›› Issue (11): 150-157.doi: 10.13475/j.fzxb.20171204208

• 机械与器材 • 上一篇    下一篇

露点间接蒸发冷却器换热效能理论与性能实验对比

    

  1.  
  • 收稿日期:2017-12-20 修回日期:2018-08-07 出版日期:2018-11-15 发布日期:2018-11-19
  • 基金资助:

     

Theoretical and experimental analysis on heat transfer performance of dew point indirect evaporative cooler

  • Received:2017-12-20 Revised:2018-08-07 Online:2018-11-15 Published:2018-11-19

摘要:

为优化露点间接蒸发冷却器结构及不同工况环境下的冷却效率、风量配比与制冷量关系等工艺,对3 种不同的露点间接蒸发冷却器(复合式、交叉式、逆流式)的技术原理、结构形式、传热传质特点进行对比分析,并在实验室模拟工况条件下对其湿球效率、露点效率、温降幅度、制冷量等性能进行测试。结果表明:干燥条件下这3 种露点冷却器的湿球效率均可达到100%以上,露点效率在55% ~85% 之间;标准干燥工况条件(干球温度为38 ℃,湿球温度为23 ℃)下,交叉式和复合式露点冷却器的进出风平均干球温降在15 ℃ 左右,进出风平均湿球温降在5.5 ℃左右,明显优于复合式露点冷却器;逆流式露点冷却器的能效比为11.78左右,达到了最高的水准。

关键词: 露点间接蒸发冷却, 传热传质, 换热芯体, 温降幅度, 冷却效率

Abstract:

In view of the optimization of the dew point indirect evaporative cooler structure, the cooling efficiency under different environmental conditions, the relationship between the air volume ratio and the cooling capacity, and the technical principle, structure, heat and mass transfer characteristics of three different dew point indirect evaporative coolers (composite , cross and countercurrent ) were compared and analyzed. At the same time, the three kinds of dew point indirect evaporative cooler were tested on the wet bulb efficiency, dew point efficiency, temperature drop range, cooling capacity and so on under the laboratory simulation conditions or practical applications. The experimental results show that under dry conditions, the wet bulb efficiency of the three dew point coolers can all reach above 100%, and the dew point efficiency is between 55% and 85%. In terms of the temperature drop range, the average dry-bulb temperature drop of the cross-type and composite dew-point coolers under standard drying conditions (dry bulb temperature of 38°℃and wet bulb temperature of 23℃) is about 15 °℃, and wet bulb temperature drop is at about 5.5 ℃, significantly better than that of the composite dew point cooler. At this point, the countercurrent dew point cooler energy effciency raio is 11.78, reaching the highest level.

Key words: dew point indirect evaporative cooling, heat and mass transfer, heat exchanger core, temperature drop rate, cooling efficiency

中图分类号: 

  •  
[1] 周小红;王善元;叶继涛;陈儿同. 低温织物微气候测试仪[J]. 纺织学报, 2003, 24(05): 54-55.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 吴俊;温盛军. BP神经网络在西服样板设计中的应用[J]. 纺织学报, 2008, 29(9): 113 -116 .
[2] 吴海培 高晓红 方婧 刘其霞 何平. 二氧化钛/还原氧化石墨烯复合材料的制备及其光催化降解脱色性能[J]. 纺织学报, 2018, 39(12): 78 -83 .
[3] 胡勇杰. 纳米二氧化硅/聚醚共聚乙酰胺防水透气涂层织物的研制及其性能[J]. 纺织学报, 2018, 39(10): 104 -109 .
[4] 王亚 黄菁菁 张如全 . 艾蒿油-壳聚糖抗菌微胶囊的制备及其应用[J]. 纺织学报, 2018, 39(10): 99 -103 .
[5] 高畅 刘基宏. 基于奇部Gabor滤波器的纱管余纱量检测[J]. 纺织学报, 2018, 39(10): 138 -142 .
[6] 蔡小雪 吴志明 董智佳. 明代中后期女袄的形制与结构特点解析[J]. 纺织学报, 2017, 38(09): 115 -119 .
[7] 孙帅 缪旭红 张灵婕 胡瑜. 经编纱线张力补偿装置的工作机制[J]. 纺织学报, 2018, 39(11): 140 -144 .
[8] 董红坤 贺辛亥 钟鹏 渠志刚 邢圆圆. 三维机织物织边造型工艺设计[J]. 纺织学报, 2017, 38(04): 50 -54 .
[9] 陈敬玉. 民族迁徙影响下的浙闽畲族服饰传承脉络[J]. 纺织学报, 2017, 38(04): 115 -120 .
[10] 蔡金芳 陈维国 崔志华 江华. 双亚芴基醌式噻吩染料对棉织物的染色性能[J]. 纺织学报, 2018, 39(10): 81 -85 .