纺织学报 ›› 2016, Vol. 37 ›› Issue (06): 101-106.

• 服装工程 • 上一篇    下一篇

衣下间隙对织物系统热湿阻的影响

  

  • 收稿日期:2015-04-17 修回日期:2016-02-04 出版日期:2016-06-15 发布日期:2016-06-17

Influence of air gaps on thermal and evaporative resistances of fabric system

  • Received:2015-04-17 Revised:2016-02-04 Online:2016-06-15 Published:2016-06-17

摘要:

为了研究人体皮肤与织物之间存在的衣下间隙对织物系统传热透湿性能的影响,实验利用出汗热平板仪测试织物系统的热阻和湿阻,并通过在热板与织物之间放置不同厚度的分隔板来模拟衣下间隙厚度,实现了定量测试皮肤—衣下间隙—织物之间的热湿传递。实验结果证明,织物系统的热阻和湿阻先随着衣下间隙厚度的增大而增加,但在衣下间隙达到12mm时出现下降,随后又一进步增加。虽然织物厚度影响着织物系统的热阻与湿阻,但衣下间隙对织物系统热湿阻的影响更为显著。综合服装的合体美观与舒适保暖性能,建议防寒类服装设计采用胸围放松量6-8cm之间为宜。

Abstract:

To investigate the effect of air gaps located between human skin and fabric on the heat and moisture transfer properties of fabric system, the sweating hot plate was used to test the thermal and evaporative insulation of fabric. The research used a spacer with different thickness to simulate different air gaps, in such way, the heat and moisture transfer through human skin-air gaps-fabric was quantificational tested. The experimental results show that the thermal and evaporative insulation of fabric system increase with the air gaps firstly, and then go down when the air gaps reaches 12mm, after that they go up again. Although the fabric thickness influence the thermal and evaporative insulation of fabric system, the experiment proves that the influence is more significant for air gaps under clothing. Taking into account of the fit and warm properties of clothing, the allowance of chest for cold protective clothing is suggested to be 6-8 cm.

No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!