Journal of Textile Research ›› 2019, Vol. 40 ›› Issue (09): 167-172.doi: 10.13475/j.fzxb.20181005606

• Apparel Engineering • Previous Articles     Next Articles

Data consistency and replaceability based on different human measurement methods

YU Jiajia, LI Jian()   

  1. School of Fashion, Beijing Institute of Fashion Technology, Beijing 100029, China
  • Received:2018-10-30 Revised:2019-06-11 Online:2019-09-15 Published:2019-09-23
  • Contact: LI Jian E-mail:jean.xiaoyu@163.com

Abstract:

In order to explore consistency and substitutability between human data results obtained by three-dimensional (3-D) scanners and manual data as well as the data equivalence between the results obtained by different scanners, this paper used HumanSolutions and [TC]2 3-D scanners to scan the samples of women between the ages of 20-35, and 30 somatotype indexes of 388 samples were manually measured by Rapidform XOR3. The consistency of the 3-D data and their corresponding manual data were checked using line chart and intraclass correlation coefficient (abbreviate it to ICC). The replaceability of the data were checked according to the national standard. With manual data as a medium, the data consistency and replaceability between two kinds of 3-D data and the real size value were compared to judge the equivalence of different 3-D data. The results show that good consistency exists between 3-D data and manual data(ICC>0.75), and the three data of Human Solutions 3-D scan, [TC]2 3-D scanning and manual measurement are replaceable on partial measurement terms, and can be used equivalently in data processing and analysis.

Key words: manual measurement method, three-dimensional scan, consistency, replaceability, intraclass correlation coefficient

CLC Number: 

  • TS941.17

Tab.1

Anthropometric items"

仪器
名称
国家 光源 扫描时间/
s
数据密度/
(字节·s-1)
准确度/
mm
Human
Solutions
德国 激光 8~20 2 000 000 5~60
[TC]2 美国 白光 8 400 000 1~2

Fig.1

Different scanner data compared with manual data (chest circumference). (a) HumanSolutions data versus manual data ;(b) [TC]2 data versus manual data"

Tab.2

C between 3-D data and manual data"

测量项目 CH CT 测量项目 CH CT
颈根围 0.977 0.855 肩幅 0.950 0.921
胸围 0.982 0.983 颈根厚 0.973 0.766
乳下围 0.994 0.974 乳点位厚 0.992 0.968
腰围 0.998 0.982 胸围位中心厚 0.997 0.946
腹部前突点围 0.998 0.960 乳下围位厚 0.985 0.960
臀围 0.996 0.951 腰围位厚 0.995 0.960
小腿最突点围 0.999 0.967 腹部前突点厚 0.984 0.940
颈根宽 0.782 0.622 臀围位厚 0.989 0.940
乳点间距 0.967 0.899 小腿最突围厚 0.896 0.913
乳点位宽 0.974 0.938 后中心长 0.949 0.846
乳下围位宽 0.972 0.946 后长 0.883 0.692
腰围位宽 0.991 0.932 前中心长 0.912 0.790
腹部前突点宽 0.992 0.913 前长 0.932 0.693
臀围位宽 0.969 0.879 肩宽1 0.599 0.292
小腿最突围宽 0.940 0.916 肩宽2 0.541 0.322

Tab.3

Replaceability of 3-D data and manual data"

测量项目 ΔH ΔT 最大允
差/cm
颈根围 [-0.2,0.4] [-0.3,0.3] 0.4
胸围 [-1.0,-0.6] [-0.2, 1.0 ] 0.9
乳下围 [-0.4,-0.2] [-0.2,0.5] 0.9
围度 腰围 [-0.2,0.5] [-0.2,1.7] 0.9
腹部前突点围 [-0.1,0.4] [-0.2,0.9] 0.9
臀围 [-0.4,-0.2] [-0.2,1.2] 0.9
小腿最突点围 [-0.4,-0.2] [-0.1,0.4] 0.4
颈根宽 [-0.5,0.2] [-0.5,-0.1] 0.4
乳点间距 [-0.2,0.3] [-0.2,0.2] 0.4
乳点位宽 [-0.6,-0.4] [-0.2,0.5] 0.4
乳下围位宽 [-0.5,-0.4] [-0.1,0.6] 0.4
宽度 腰围位宽 [0.2, 0.7] [-0.1,1.3] 0.4
腹部前突点位宽 [-0.2,0.1] [-0.1,0.8] 0.4
臀围位宽 [-0.6,-0.4] [-0.1,1.5] 0.4
小腿最突围宽 [0.1,0.7] [-0.1,1.1] 0.4
肩幅(SP1) [0.3,0.7] [-0.1, 0.5] 0.4
颈根厚 [0.2,0.4] [-0.1,0.3] 0.5
乳头点位厚 [0.1,0.7] [-0.1,1.3] 0.5
胸围位中心厚 [0.1,0.3] [-0.2,1.6] 0.5
厚度 乳下围位厚 [0.0,0.6] [-0.1,1.1] 0.5
腰围位厚 [0.0,0.3] [-0.1,1.2] 0.5
腹部前突点厚 [0.1,0.6] [-0.1,0.7] 0.5
臀围位厚 [-0.1,0.3] [-0.1,1.5] 0.5
小腿最突围厚 [-0.1,0.5] [-0.1,1.3] 0.5
后中心长 [0.7,1.0] [0.5,0.7] 0.5
后长 [0.3,0.5] [-0.3,0.5] 0.5
实长 前中心长 [-0.8,-0.5] [-0.7,-0.2] 0.5
前长 [-0.5,-0.3] [-0.4, 0.4] 0.5
肩宽2 [-0.1,0.2] [-0.5,-0.2] 0.5
肩宽1 [-0.5,-0.1] [-0.2,0.5] 0.5

Fig.2

Points cloud comparison between HumanSolutions and [TC]2"

Fig.3

[TC]2-cross section of waist point cloud"

[1] 席焕久, 陈昭. 人体测量方法[M].2版. 北京: 科学出版社, 2010: 318.
XI Huanjiu, CHEN Zhao. Anthropometric Methods[M].2nd ed. Beijing: Science Press, 2010: 318.
[2] 刘咏梅, 张小雪, 郭云昕. 国内外服装用人体数据库调查与分析[J]. 纺织学报, 2015,36(6):141-147.
LIU Yongmei, ZHANG Xiaoxue, GUO Yunxin. Survey and analysis on domestic and overse as human body database for garments'use[J]. Journal of Textile Reasearch, 2015,36(6):141-147.
[3] 李镒冲, 李晓松. 两种测量方法定量测量结果的一致性评价[J]. 现代预防医学, 2007,34(17):3263-3266.
LI Yichong, LI Xiaosong. Evaluation on different assessment methods of consistency of quantitatice measurements[J]. Modern Preventive Medicine, 2007,34(17):3263-3266.
[4] 张淑君, 丁笑君, 邹奉元. 三维人体扫描仪测量数据与手工测量数据关系研究[J]. 浙江理工大学学报(自然科学版), 2006,23(3):298-301.
ZHANG Shujun, DING Xiaojun, ZOU Fengyuan. Research on the relationship between data extracted from 3D body scanner and manual data[J]. Journal of Zhejiang Sci-Tech University(Natural Sciences Edition), 2006,23(3):298-301.
[5] 邹奉元, 张颖. 基于不同方法的人体测量数据重复性研究[J]. 纺织学报, 2004,25(4):71-71.
ZOU Fengyuan, ZHANG Ying. Research on repeatability of anthropometric data based ondifferent methods[J]. Journal of Textile Reasearch, 2004,25(4):71-73.
[6] LI J, ZHENG R, ZHANG H, et al. A Comparative Study on anthropometric data from different body measuring methods. [C]//LI Y,LIU YF, L XN, et al. Textile Bioengineering and Informatics Symposium Proceeding. Hong Kong: Binary Information Press, 2011: 104-111.
[7] 徐继红, 张文斌. 非接触式三维人体扫描技术的综述[J]. 扬州职业大学学报, 2006,10(3):49-53.
XU Jihong, ZHANG Wenbin. Review of noncontact 3D body scanning technology[J]. Journal of Yangzhou Polytechnic College, 2006,10(3):49-53.
[8] BARTKO J J. The intraclass correlation coefficient as a measure of reliability[J]. Psycholog Rep, 1966,19(1):3.
[9] 余红梅, 罗艳虹, 萨建, 等. 组内相关系数及其软件实现[J]. 中国卫生统计, 2011,28(5):497-500.
YU Hongmei, LUO Yanhong, SA Jian, et al. Intraclass correlation coefficient and software procedures[J]. Chinese Journal of Health Statistics, 2011,28(5):497-500.
[10] 潘晓平, 倪宗瓒. 组内相关系数在信度评价中的应用[J]. 四川大学学报(医学版), 1999,30(1):62-63.
PAN Xiaoping, NI Zongzan. Application of intraclass correlation coefficient to reliability assessment[J]. Journal of Sichuan University(Medical Science Edition), 1999,30(1):62-63.
[11] 李雪君. 呼吸对人体尺寸的影响[J]. 纺织科技进展, 2015(6):59-61.
LI Xuejun. Influence of breathing on body dimen-sion[J]. Progress in Textile Science & Technology, 2015(6):59-61.
[1] . In fluence of sleeveless fitted cheongsam waist dart distribution on apparel modeling [J]. JOURNAL OF TEXTILE RESEARCH, 2018, 39(08): 105-109.
[2] . Design and development of alkali consistency online monitoring system for mercerizing machine based on measurement of alkali density [J]. JOURNAL OF TEXTILE RESEARCH, 2014, 35(12): 126-0.
[3] LUO Zhiping;DING Hao;ZHANG Yongyu. Technology for transfer needle grooves machining [J]. JOURNAL OF TEXTILE RESEARCH, 2010, 31(10): 129-133.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!