JOURNAL OF TEXTILE RESEARCH ›› 2010, Vol. 31 ›› Issue (2): 101-105.

• 机械与器材 • Previous Articles     Next Articles

Effect of voltage and gauge of static electricity plate on nep of card sliver

CAO Ji-peng;WANG Rui;SUN Peng-zi   

  • Received:2009-03-10 Revised:2009-07-05 Online:2010-02-15 Published:2010-02-15

Abstract:

A self-made web cleaner with electrostatic plate was installed on the back plate of a carding machine. The card sliver produced under different conditions was tested by USTER AFIS. The results show that this device can reduce the content and size of neps under appropriate gauge and voltage. When the gauge between electrostatic plate and cylinder is 1 mm, a scheme with 1500 V voltage is more effective, the content and size of neps are 6.9% and 5.7% respectively,which is less than those when no voltage is applied. The content and size of seed coat neps (SCN) reduce 42.9% and 4.0% respectively. When the gauge is 2 mm, a scheme with 4000 V voltage is effective, the content and size of neps reduce 8.7% and 5.5% respectively. The content and size of seed coat neps (SCN) reduce 25% and 4.3% respectively. When the gauge is 3 mm, the contents and size of neps and SCN aren’t improved under any voltage of this experiment in comparison with those when no voltage is applied.

CLC Number: 

  • TS 103.22
[1] . Influences of cylinder speed-change mechanism parameter for processing property on high-speed comber [J]. JOURNAL OF TEXTILE RESEARCH, 2014, 35(12): 110-0.
[2] . Lap pressure mechanism and its pressure of HC181 Unilap [J]. JOURNAL OF TEXTILE RESEARCH, 2013, 34(7): 115-120.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!